Complaints about the 2012 Coachmen Prism peaked in 2015, with 1 filed
Owner complaints about this model year, by the year they were filed with NHTSA.
Other, diesel, built in Germany. Owner complaints on file from Jan 28, 2015 to Aug 23, 2021.
Owner complaints about this model year, by the year they were filed with NHTSA.
Owner complaints by component. Hover or focus a bar for the crash, fire, injury or death count.
Check a specific vehicle by VIN on NHTSA's site: a campaign may cover only part of a model year's production.
| Campaign | Filed | Subject | Component | Vehicles | Remedy |
|---|---|---|---|---|---|
| 17V-756 | Nov 22, 2017 | These extinguishers may become clogged, preventing the extinguisher from discharging as expected or excessive force may be needed to activate the… | Equipment | 365,885 | Part replacement |
| 16V-267 | May 3, 2016 | Upon deployment of the driver's frontal air bag, excessive internal pressure may cause the inflator to rupture | Airbags | 77 | Part replacement |
| 15V-798 | Nov 25, 2015 | Affected vehicles are equipped with certain Lippert-brand Coachstep Double and Triple Electric Steps | Equipment | 9,687 | Repair or modification |
| 14V-499 | Aug 13, 2014 | Due to the welds being in an improper location, the liquid propane (LP) tank support braces may not be secure, allowing the LP tank to drop and… | Equipment | 256 | Repair or modification |
The full text of every complaint filed with NHTSA about this model year, newest first. Complaints are filed by owners and are not verified by NHTSA; NHTSA removes personal details before publishing.
2 complaints on file, page 1 of 1.
My motorhome does not have an emergency escape window.
NHTSA complaint 11430142TL* THE CONTACT OWNS A 2012 COACHMEN PRISM. THE CONTACT STATED THAT A BANGING NOISE EMITTED FROM THE REAR END OF THE VEHICLE. AFTER INSPECTING THE VEHICLE, THE CONTACT NOTICED THAT THE PROPANE TANKS SHIELD WELD HAD FRACTURED AND WAS HANGING FROM THE VEHICLE. THE CONTACT USED BUNGEE CORDS TO TEMPORARILY HOLD UP THE SHIELD UNTIL HE REACHED THE CLOSEST REPAIR FACILITY. THE TECHNICIAN STATED THAT THE ORIGINAL WELDS THAT HELD THE TANK WERE OF VERY POOR QUALITY. THE MECHANIC RELOCATED THE TANK ABOVE OF THE ANGLE ARM INSTEAD OF BELOW IT AND BOLTED THE TANK TO PREVENT THE FAILURE FROM RECURRING. THE MANUFACTURER WAS MADE AWARE OF THE FAILURE. THE VEHICLE WAS REPAIRED. THE FAILURE MILEAGE WAS 18,000. UPDATED 03/24/15*LJ THE CONSUMER STATED BOTH WELDS BROKE AT DIFFERNET TIMES BETEWEEN A HEAT DETECTION SHIELD BETWEEN THE PROPANE TANK AND EXHAUST SYSTEM. UPDATED 05/26/15*JB
NHTSA complaint 10679446Technical service bulletins and other notices the manufacturer sent to dealers. A bulletin is not a recall.